What if the melt pump motor is overloaded?

inquirysales@battemachinery.com

Melt pump in the use of the process will appear this or that kind of failure and problem, today we do a motor overload on the problem of cause analysis and treatment methods to summarize:

1. Cause analysis: the specific gravity of the inhalation medium or annual too large, treatment: adjustment of the specific gravity of the medium or viscosity.

2. cause analysis: the export filter pressure difference is too large, treatment: check and clean the export filter.

3. Cause analysis: motor shaft bending, treatment: check the shaft.

extrusion melt pump

4. Cause analysis: packing too tight, treatment: adjust the tight force.

5. Cause analysis: motor failure, treatment: repair or replacement.

6. Cause analysis: coupling coaxiality is too poor, treatment: recalibration.

7. Cause Analysis: Discharge pressure is too high, treatment: reduce the discharge pressure.